Assessment Year | 1998 |
---|---|
Principal Product | Fiberglass Motor Home Parts |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 81 |
Plant Area |
80,000
ft2
|
Annual Production | 30,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,382 | 1,215,709 |
kWh
|
$0.081 |
Electricity Demand | $42,438 | 5,004 |
kW-mo/yr
|
$8.48 |
Natural Gas | $13,463 | 2,151 |
MMBtu
|
$6.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $376,689 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,856 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,633 | $14,800 |
$2,924
35,756
kWh
|
$1,709
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,315 | $950 |
$2,712
33,411
kWh
|
$1,603
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4224: Upgrade controls on compressors | $2,717 | $5,000 |
$1,759
21,688
kWh
|
$958
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.7261: Install timers and/or thermostats | $993 | $900 |
$993
12,309
kWh
|
- | - | - | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,311 | - |
$811
9,965
kWh
|
$500
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $1,157 | $1,125 | - | - |
$1,157
-
MMBtu
|
- | - | - | |
07 | 2.4322: Use or replace with energy efficient substitutes | $844 | $2,865 | - | - |
$844
-
MMBtu
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,268 | $9,327 |
$2,181
26,671
kWh
|
$1,087
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.7144: Install spectral reflectors / delamp | $2,966 | $3,120 |
$2,020
24,912
kWh
|
$946
-
kW-mo/yr
|
- | - | - | - | |
10 | 2.4322: Use or replace with energy efficient substitutes | $338,670 | $24,000 | - | - | - | - |
$338,670
-
lb
|
- | |
11 | 3.6112: Use filter and drying oven to reduce sludge volume | $3,800 | $1,200 | - | - | - |
$3,800
-
gal
|
- | - | |
12 | 3.7131: Use a rag recycle service | $8,640 | $200 | - | - | - | - |
$8,640
-
lb
|
- | |
13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,375 | $4,864 | - | - | - | - | - | $3,375 | |
TOTAL RECOMMENDED | $376,689 | $68,351 |
$13,400
164,712
kWh
|
$6,803
-
kW-mo/yr
|
$2,001
-
MMBtu
|
$3,800
-
gal
|
$347,310
-
lb
|
$3,375 | ||
TOTAL IMPLEMENTED | $20,856 | $25,277 |
$7,817
95,838
kWh
|
$4,399
-
kW-mo/yr
|
- | - |
$8,640
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs