ITAC Assessment: RU0081
ITAC logo
ITAC Assessment: RU0081
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1990
Principal Product FOAM CARPET PADDING
NAICS
n/a
SIC 2299: Textile goods, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 47
Plant Area
n/a
Annual Production 135,000
thousand feet
Production Hrs. Annual 4,250
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $230,370 2,279,015
kWh
Natural Gas $33,148 8,229
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $20,102 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,133

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,465 $350 $1,465
14,654
kWh
-
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,110 - $2,110
20,809
kWh
-
03 2.4312: Improve lubrication practices $3,237 $800 $3,237
31,946
kWh
-
04 2.4133: Use most efficient type of electric motors $4,558 $11,400 $4,558
45,135
kWh
-
05 2.7243: Improve air circulation with destratification fans / other methods $2,360 $3,240 $(-360.0)
(-3,517)
kWh
$2,720
-
MMBtu
06 2.6212: Turn off equipment during breaks, reduce operating time $4,212 - $4,212
41,618
kWh
-
07 2.7444: Close holes and openings in building such as broken windows $2,160 $565 - $2,160
-
MMBtu
TOTAL RECOMMENDED $20,102 $16,355 $15,222
150,645
kWh
$4,880
-
MMBtu
TOTAL IMPLEMENTED $8,133 $11,750 $8,133
80,598
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs