Assessment Year | 1987 |
---|---|
Principal Product | PVC PIPE EXTRUSIONS |
NAICS |
n/a
|
SIC | 3084: Plastics Pipe |
Sales Range | $10 M to 50M |
# of Employees | 40 |
Plant Area |
n/a
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $266,800 | 4,099,941 |
kWh
|
$0.065 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,937 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,041 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,704 | - |
$2,704
41,618
kWh
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $358 | $96 |
$358
5,569
kWh
|
|
03 | 2.2511: Insulate bare equipment | $2,412 | $130 |
$2,412
37,222
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $531 | $368 |
$531
8,206
kWh
|
|
05 | 2.7492: Use proper thickness of insulation on building envelope | $1,538 | $3,132 |
$1,538
23,740
kWh
|
|
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,394 | $800 |
$3,394
52,169
kWh
|
|
TOTAL RECOMMENDED | $10,937 | $4,526 |
$10,937
168,524
kWh
|
||
TOTAL IMPLEMENTED | $9,041 | $1,298 |
$9,041
139,215
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs