| Assessment Year | 1987 |
|---|---|
| Principal Product | PVC PIPE EXTRUSIONS |
| NAICS |
n/a
|
| SIC | 3084: Plastics Pipe |
| Sales Range | $10 M to 50M |
| # of Employees | 40 |
| Plant Area |
n/a
|
| Annual Production | 12,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $266,800 | 4,099,941 |
kWh
|
$0.065 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $10,937 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,041 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,704 | - |
$2,704
41,618
kWh
|
|
| 02 | 2.4221: Install compressor air intakes in coolest locations | $358 | $96 |
$358
5,569
kWh
|
|
| 03 | 2.2511: Insulate bare equipment | $2,412 | $130 |
$2,412
37,222
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $531 | $368 |
$531
8,206
kWh
|
|
| 05 | 2.7492: Use proper thickness of insulation on building envelope | $1,538 | $3,132 |
$1,538
23,740
kWh
|
|
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,394 | $800 |
$3,394
52,169
kWh
|
|
| TOTAL RECOMMENDED | $10,937 | $4,526 |
$10,937
168,524
kWh
|
||
| TOTAL IMPLEMENTED | $9,041 | $1,298 |
$9,041
139,215
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||