| Assessment Year | 1988 |
|---|---|
| Principal Product | LASER TRIMMER SYSTEMS |
| NAICS |
n/a
|
| SIC | 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere |
| Sales Range | $10 M to 50M |
| # of Employees | 540 |
| Plant Area |
n/a
|
| Annual Production | 80
pieces
|
| Production Hrs. Annual | 2,100
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $216,711 | 4,162,661 |
kWh
|
$0.052 |
| Natural Gas | $2,315 | 408 |
MMBtu
|
$5.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $33,947 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $31,958 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.6232: Install set-back timers | $1,607 | - |
$1,607
27,550
kWh
|
- | - | |
| 02 | 2.7261: Install timers and/or thermostats | $28,590 | $1,000 |
$27,154
522,274
kWh
|
$1,436
-
MMBtu
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $382 | $100 |
$382
7,327
kWh
|
- | - | |
| 04 | 2.2511: Insulate bare equipment | $2,666 | $3,230 |
$2,666
51,290
kWh
|
- | - | |
| 05 | 3.4115: Recover and reuse cooling water | $702 | $2,050 | - | - | $702 | |
| TOTAL RECOMMENDED | $33,947 | $6,380 |
$31,809
608,441
kWh
|
$1,436
-
MMBtu
|
$702 | ||
| TOTAL IMPLEMENTED | $31,958 | $6,280 |
$29,820
573,564
kWh
|
$1,436
-
MMBtu
|
$702 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs