| Assessment Year | 2011 |
|---|---|
| Principal Product | Car seat frames |
| NAICS | 336360: Motor Vehicle Seating and Interior Trim Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $100 M to 500M |
| # of Employees | 535 |
| Plant Area |
230,000
ft2
|
| Annual Production | 999,999,999,999
units
|
| Production Hrs. Annual | 5,880
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $577,369 | 10,911,600 |
kWh
|
$0.053 |
| Electricity Demand | $119,697 | 29,329 |
kW-mo/yr
|
$4.08 |
| Electricity Fees | $92,739 | - |
|
- |
| Natural Gas | $103,914 | 9,266 |
MMBtu
|
$11.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $168,098 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $33,453 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $62,618 | $96,027 |
$49,681
938,920
kWh
|
$5,586
-
kW-mo/yr
|
$7,351 | |
| 02 | 2.7135: Install occupancy sensors | $2,105 | $2,719 |
$1,858
35,118
kWh
|
- | $247 | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $31,348 | - |
$27,668
522,934
kWh
|
- | $3,680 | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $24,723 | $640 |
$18,710
353,622
kWh
|
$3,525
-
kW-mo/yr
|
$2,488 | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,016 | $3,900 |
$2,972
56,176
kWh
|
$602
-
kW-mo/yr
|
$442 | |
| 06 | 2.7243: Improve air circulation with destratification fans / other methods | $20,451 | $66,050 |
$18,050
341,143
kWh
|
- | $2,401 | |
| 07 | 2.2437: Recover waste heat from equipment | $22,837 | $1,752 |
$20,156
380,946
kWh
|
- | $2,681 | |
| TOTAL RECOMMENDED | $168,098 | $171,088 |
$139,095
2,628,859
kWh
|
$9,713
-
kW-mo/yr
|
$19,290 | ||
| TOTAL IMPLEMENTED | $33,453 | $2,719 |
$29,526
558,052
kWh
|
- | $3,927 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs