Assessment Year | 2017 |
---|---|
Principal Product | Aerospace machining |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3364: Nonferrous Die-Castings, Except Aluminum |
Sales Range | $5 M to 10M |
# of Employees | 38 |
Plant Area |
24,000
ft2
|
Annual Production | 40,000
units
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $47,067 | 687,320 |
kWh
|
$0.068 | |
Electricity Demand | $10,809 | 1,858 |
kW-mo/yr
|
$5.82 | |
Electricity Fees | $21,048 | - |
|
- | |
Natural Gas | $2,851 | 399 |
MMBtu
|
$7.15 | |
Waste Disposal Costs | |||||
Water Usage | $2,362 | 131 |
Tgal
|
$18.03 | |
TOTAL YEARLY COSTS | $84,137 | ||||
RECOMMENDED SAVINGS* | $18,585 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $9,284 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7241: Install outside air damper / economizer on hvac unit | $6,242 | $3,615 |
$6,242
91,793
kWh
|
- | - | - | |
02 | 2.2622: Replace existing chiller with high efficiency model | $1,799 | $6,750 |
$1,082
15,914
kWh
|
$717
-
kW-mo/yr
|
- | - | |
03 | 2.7211: Clean and maintain refrigerant condensers and towers | $600 | $160 |
$437
6,420
kWh
|
$163
-
kW-mo/yr
|
- | - | |
04 | 2.6232: Install set-back timers | $378 | $599 |
$286
4,204
kWh
|
- | - |
$92
-
MMBtu
|
|
05 | 2.6127: Maintain air filters by cleaning or replacement | $311 | $480 |
$311
4,580
kWh
|
- | - | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $304 | $90 |
$73
1,067
kWh
|
- | - |
$232
-
MMBtu
|
|
07 | 2.4322: Use or replace with energy efficient substitutes | $2,765 | $1,260 |
$2,765
40,660
kWh
|
- | - | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,622 | $680 |
$1,622
23,847
kWh
|
- | - | - | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $712 | $2,381 |
$712
10,469
kWh
|
- | - | - | |
10 | 2.4221: Install compressor air intakes in coolest locations | $487 | $1,180 |
$487
7,157
kWh
|
- | - | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,547 | $7,040 |
$2,240
32,947
kWh
|
$307
-
kW-mo/yr
|
- | - | |
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $264 | $1,120 |
$264
3,875
kWh
|
- | - | - | |
13 | 2.8123: Pay utility bills on time | $554 | - | - | - | $554 | - | |
TOTAL RECOMMENDED | $18,585 | $25,355 |
$16,520
242,933
kWh
|
$1,187
-
kW-mo/yr
|
$554 |
$324
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,284 | $8,415 |
$8,474
124,623
kWh
|
$163
-
kW-mo/yr
|
$554 |
$92
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs