Assessment Year | 1992 |
---|---|
Principal Product | DUPLEXERS |
NAICS |
n/a
|
SIC | 3663: Radio and Television Broadcasting and Communications Equipment |
Sales Range | $1 M to 5M |
# of Employees | 70 |
Plant Area |
n/a
|
Annual Production | 572,425
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $61,726 | 960,727 |
kWh
|
$0.064 |
Natural Gas | $11,130 | 3,317 |
MMBtu
|
$3.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,482 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,252 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $11,000 | $60,000 |
$11,000
320,633
kWh
|
- | - | |
02 | 2.3212: Optimize plant power factor | $959 | $1,225 |
$959
-
kWh
|
- | - | |
03 | 2.7261: Install timers and/or thermostats | $2,929 | $1,200 | - |
$2,929
-
MMBtu
|
- | |
04 | 2.7123: Keep lamps and reflectors clean | $2,442 | $9,361 |
$2,676
42,790
kWh
|
$(-234.0)
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,824 | $941 |
$261
6,155
kWh
|
$(-25.0)
-
MMBtu
|
$1,588 | |
06 | 2.3132: Recharge batteries on during off-peak demand periods | $1,156 | $144 |
$1,156
-
kWh
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $562 | $752 |
$562
16,413
kWh
|
- | - | |
08 | 2.6232: Install set-back timers | $230 | $290 |
$230
6,741
kWh
|
- | - | |
09 | 2.2522: Isolate hot or cold equipment | $194 | $289 |
$194
5,569
kWh
|
- | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $186 | $554 |
$186
5,569
kWh
|
- | - | |
TOTAL RECOMMENDED | $21,482 | $74,756 |
$17,224
403,870
kWh
|
$2,670
-
MMBtu
|
$1,588 | ||
TOTAL IMPLEMENTED | $16,252 | $71,633 |
$14,923
398,301
kWh
|
$(-259.0)
-
MMBtu
|
$1,588 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs