| Assessment Year | 1983 |
|---|---|
| Principal Product | MENS T-SHIRTS |
| NAICS |
n/a
|
| SIC | 2321: Men's and Boys' Shirts, Except Work Shirts |
| Sales Range | $10 M to 50M |
| # of Employees | 180 |
| Plant Area |
n/a
|
| Annual Production | 475,000
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $30,128 | 799,238 |
kWh
|
$0.038 |
| Natural Gas | $260 | 41 |
MMBtu
|
$6.34 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,538 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7251: Reduce air conditioning load by evaporating water from roof | $3,355 | $9,600 |
$3,355
70,047
kWh
|
|
| 02 | 2.7422: Plant trees or shrubs near windows to shield from sunlight | $664 | $442 |
$664
12,896
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,083 | $646 |
$2,083
43,376
kWh
|
|
| 04 | 2.7226: Use computer programs to optimize hvac performance | $2,856 | $10,000 |
$2,856
59,496
kWh
|
|
| 05 | 2.7261: Install timers and/or thermostats | $2,180 | $1,000 |
$2,180
45,428
kWh
|
|
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $884 | $1,500 |
$884
18,464
kWh
|
|
| 07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $516 | $352 |
$516
10,844
kWh
|
|
| TOTAL RECOMMENDED | $12,538 | $23,540 |
$12,538
260,551
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs