Assessment Year | 2000 |
---|---|
Principal Product | Automotive Seating |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
83,000
ft2
|
Annual Production | 193,000
pieces
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $33,528 | 2,035,170 |
kWh
|
$0.016 |
Electricity Demand | $54,119 | 5,290 |
kW-mo/yr
|
$10.23 |
Electricity Fees | $3,567 | - |
|
- |
Natural Gas | $10,754 | 1,969 |
MMBtu
|
$5.46 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,043 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,483 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $125 | $100 |
$125
7,620
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,121 | $6,762 |
$663
40,152
kWh
|
$1,458
-
kW-mo/yr
|
- | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $13,997 | $11,000 |
$5,453
330,891
kWh
|
$15,506
-
kW-mo/yr
|
$(-6,962.0)
-
MMBtu
|
|
04 | 2.7442: Keep doors and windows shut when not on use | $115 | - |
$115
6,448
kWh
|
- | - | |
05 | 2.4151: Develop a repair/replace policy | $360 | $843 |
$131
7,913
kWh
|
$229
-
kW-mo/yr
|
- | |
06 | 2.2211: Use optimum temperature | $10 | $8 |
$10
586
kWh
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $236 | $900 |
$126
7,620
kWh
|
$110
-
kW-mo/yr
|
- | |
08 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $79 | $340 |
$110
4,982
kWh
|
$82
-
kW-mo/yr
|
$(-113.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $17,043 | $19,953 |
$6,733
406,212
kWh
|
$17,385
-
kW-mo/yr
|
$(-7,075.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $14,483 | $12,008 |
$5,829
353,165
kWh
|
$15,616
-
kW-mo/yr
|
$(-6,962.0)
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs