Assessment Year 2000
Principal Product Lumber Processing
NAICS
n/a
SIC 2491: Wood Preserving
Sales Range $50
M
to 100
M
# of Employees 140
Plant Area 200,000
ft2
Annual Production 120,000
thousand feet
Production Hrs. Annual 5,610
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $119,065 2,313,599
kWh
Electricity Demand $39,219 9,341
kW-mo/yr
Electricity Fees $1,365 -
Natural Gas $33,572 7,317
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $13,534 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.4151: Develop a repair/replace policy $4,286 $13,061 $2,858
59,496
kWh
$746
-
kW-mo/yr
- - - - $682
02 2.7447: Install vinyl strip / high speed / air curtain doors $5,684 $10,854 - - - $5,684
-
MMBtu
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,135 $4,118 $956
19,930
kWh
$179
-
kW-mo/yr
- - - - -
04 2.4221: Install compressor air intakes in coolest locations $534 $500 $510
10,551
kWh
$24
-
kW-mo/yr
- - - - -
05 2.7124: Make a practice of turning off lights when not needed $444 $20 $397
8,206
kWh
$47
-
kW-mo/yr
- - - - -
06 2.1311: Replace electrically-operated equipment with fossil fuel equipment $297 $450 $262
5,569
kWh
$141
-
kW-mo/yr
- $(-106.0)
-
MMBtu
- - -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $85 $25 $85
1,758
kWh
- - - - - -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $617 $800 $151
3,224
kWh
$18
-
kW-mo/yr
- - $308 $140 -
09 4.611: Begin a practice of predictive / preventative maintenance $221 $468 - - - - $221 - -
10 4.811: Demolish old building to reduce tax and insurance bills $121 $250 - - $121 - - - -
11 4.821: Pay bills on time to avoid late fees $110 - - - $110 - - - -
TOTAL RECOMMENDED $13,534 $30,546 $5,219
108,734
kWh
$1,155
-
kW-mo/yr
$231 $5,578
-
MMBtu
$529 $140 $682
TOTAL IMPLEMENTED - - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs