Assessment Year 2014
Principal Product Concrete parts
NAICS 327390: Other Concrete Product Manufacturing
SIC 3272: Concrete Products, Except Block and Brick
Sales Range $5
M
to 10
M
# of Employees 48
Plant Area 50,000
ft2
Annual Production 81,000,000
lb
Production Hrs. Annual 3,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $33,537 504,660
kWh
Electricity Demand $10,091 2,439
kW-mo/yr
Natural Gas $11,401 1,322
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $17,355 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,283

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $8,354 $28,643 $6,169
94,908
kWh
$1,572
-
kW-mo/yr
- - $613
02 2.4226: Use / purchase optimum sized compressor $5,218 $5,000 $4,291
66,021
kWh
$927
-
kW-mo/yr
- - -
03 2.2437: Recover waste heat from equipment $804 $1,000 - - $804
-
MMBtu
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $359 $650 $286
4,404
kWh
$73
-
kW-mo/yr
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $327 $50 $404
6,210
kWh
$103
-
kW-mo/yr
- $(-100.0) $(-80.0)
06 2.4239: Eliminate or reduce compressed air usage $114 $60 $57
873
kWh
$57
-
kW-mo/yr
- - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $602 $160 $278
4,275
kWh
$24
-
kW-mo/yr
- - $300
08 2.7134: Use photocell controls $211 $40 $211
3,240
kWh
- - - -
09 2.7135: Install occupancy sensors $134 $200 $134
2,063
kWh
- - - -
10 2.4151: Develop a repair/replace policy $1,232 $4,256 $982
15,111
kWh
$250
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $17,355 $40,059 $12,812
197,105
kWh
$3,006
-
kW-mo/yr
$804
-
MMBtu
$(-100.0) $833
TOTAL IMPLEMENTED $9,283 $28,853 $6,851
105,393
kWh
$1,699
-
kW-mo/yr
- $(-100.0) $833
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs