| Assessment Year | 2026 |
|---|---|
| Principal Product | Auto parts assembly |
| NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $100 M to 500M |
| # of Employees | 156 |
| Plant Area |
256,000
ft2
|
| Annual Production | 350,000
units
|
| Production Hrs. Annual | 6,084
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $234,921 | 2,570,963 |
kWh
|
$0.091 | |
| Natural Gas | $140,933 | 24,495 |
MMBtu
|
$5.75 | |
| Waste Disposal Costs | |||||
| Water Usage | $6,835 | 298 |
Tgal
|
$22.92 | |
| TOTAL YEARLY COSTS | $382,689 | ||||
| RECOMMENDED SAVINGS* | $131,717 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $78,892 | $102,596 |
$(-3,210.5)
(-35,280)
kWh
|
$82,103
-
MMBtu
|
- | - | |
| 02 | 2.8121: Apply for tax-free status for energy purchases | $33,832 | - | - | - | $33,832 | - | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,763 | $6,553 |
$1,763
19,372
kWh
|
- | - | - | |
| 04 | 2.6125: Keep equipment clean | $11,720 | - |
$11,720
128,794
kWh
|
- | - | - | |
| 05 | 2.6218: Turn off equipment when not in use | $118 | - |
$118
1,299
kWh
|
- | - | - | |
| 06 | 2.6218: Turn off equipment when not in use | $1,224 | $30 |
$644
7,079
kWh
|
- | - | $580 | |
| 07 | 2.7135: Install occupancy sensors | $283 | $620 |
$283
3,113
kWh
|
- | - | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $251 | $1,008 |
$251
2,759
kWh
|
- | - | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,174 | $3,351 |
$1,174
12,901
kWh
|
- | - | - | |
| 10 | 2.7261: Install timers and/or thermostats | $1,758 | $69 | - |
$1,758
-
MMBtu
|
- | - | |
| 11 | 2.7423: Reduce heat gain by window tinting | $702 | $180 |
$702
7,713
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $131,717 | $114,407 |
$13,445
147,749
kWh
|
$83,860
-
MMBtu
|
$33,832 | $580 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs