Assessment Year | 2024 |
---|---|
Principal Product | Cheese |
NAICS | 311513: Cheese Manufacturing |
SIC | 2022: Natural, Processed, and Imitation Cheese |
Sales Range | $10 M to 50M |
# of Employees | 242 |
Plant Area |
267,546
ft2
|
Annual Production | 182,500,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $894,706 | 20,042,400 |
kWh
|
$0.045 |
Electricity Demand | $212,580 | 32,639 |
kW-mo/yr
|
$6.51 |
Electricity Fees | $13,213 | - |
|
- |
Natural Gas | $141,624 | 14,738 |
MMBtu
|
$9.61 |
Other Energy | $1,882,993 | 200,971 |
MMBtu
|
$9.37 |
TOTAL YEARLY COSTS | $3,145,116 | |||
RECOMMENDED SAVINGS* | $161,602 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Energy Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,039 | - |
$2,039
45,687
kWh
|
- | - | - | |
02 | 2.2437: Recover waste heat from equipment | $10,927 | $3,514 | - | - |
$10,927
-
MMBtu
|
- | |
03 | 2.2437: Recover waste heat from equipment | $32,971 | $41,770 | - | - | - |
$32,971
-
MMBtu
|
|
04 | 2.9114: Use solar heat to make electricty | $112,659 | $399,900 |
$81,419
1,823,594
kWh
|
$31,240
-
kW-mo/yr
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,006 | $11,189 |
$2,467
55,259
kWh
|
$539
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $161,602 | $456,373 |
$85,925
1,924,540
kWh
|
$31,779
-
kW-mo/yr
|
$10,927
-
MMBtu
|
$32,971
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs