ITAC Assessment: MU0075
ITAC logo
ITAC Assessment: MU0075
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Automotive Parts
NAICS 336320: Motor Vehicle Electrical and Electronic Equipment Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $50
M
to 100
M
# of Employees 144
Plant Area 142,000
ft2
Annual Production 464,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $176,443 2,762,272
kWh
Electricity Demand $42,744 6,136
kW-mo/yr
Electricity Fees $44,370 -
Natural Gas $70,223 7,118
MMBtu
Other Gas $25,722 1
MMBtu
TOTAL YEARLY COSTS $359,502
RECOMMENDED SAVINGS* $79,415 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.8121: Apply for tax-free status for energy purchases $21,227 - - - - $21,227
02 4.425: Eliminate/reduce redundant inspections $19,774 - $14,459
225,920
kWh
$5,315
-
kW-mo/yr
- -
03 2.4227: Use compressor air filters $1,622 $5,814 $1,341
20,955
kWh
$281
-
kW-mo/yr
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $1,999 - $1,652
25,819
kWh
$346
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $217 $80 $180
2,808
kWh
$38
-
kW-mo/yr
- -
06 2.4322: Use or replace with energy efficient substitutes $12,629 $80,450 $10,443
163,179
kWh
$2,186
-
kW-mo/yr
- -
07 2.6218: Turn off equipment when not in use $7,006 - $5,794
90,531
kWh
$1,212
-
kW-mo/yr
- -
08 2.7111: Reduce illumination to minimum necessary levels $685 - $543
8,487
kWh
$142
-
kW-mo/yr
- -
09 2.7135: Install occupancy sensors $264 $138 $204
3,182
kWh
$61
-
kW-mo/yr
- -
10 2.7221: Lower temperature during the winter season and vice-versa $5,080 - $936
14,630
kWh
$437
-
kW-mo/yr
$3,707
-
MMBtu
-
11 2.7231: Use radiant heater for spot heating $6,878 $14,109 - - $6,878
-
MMBtu
-
12 2.7261: Install timers and/or thermostats $986 $836 $813
12,697
kWh
$173
-
kW-mo/yr
- -
13 2.7444: Close holes and openings in building such as broken windows $659 $513 $38
589
kWh
$8
-
kW-mo/yr
$613
-
MMBtu
-
14 4.821: Pay bills on time to avoid late fees $388 - - - - $388
TOTAL RECOMMENDED $79,415 $101,940 $36,403
568,797
kWh
$10,198
-
kW-mo/yr
$11,199
-
MMBtu
$21,615
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings