ITAC Assessment: MU0068
ITAC logo
ITAC Assessment: MU0068
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Metal Stamping Tools
NAICS 333514: Special Die and Tool, Die Set, Jig, and Fixture Manufacturing
SIC 3354: Aluminum Extruded Products
Sales Range $10
M
to 50
M
# of Employees 31
Plant Area 64,000
ft2
Annual Production 20
units
Production Hrs. Annual 2,740
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $23,787 637,249
kWh
Electricity Demand $44,743 1,392
kW-mo/yr
Electricity Fees $16,411 -
Natural Gas $7,058 937
MMBtu
LPG $76,307 3,187
MMBtu
Other Gas $1,127 1
MMBtu
Waste Disposal Costs
Water Usage $1,453 231
Tgal
TOTAL YEARLY COSTS $170,886
RECOMMENDED SAVINGS* $102,096 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings LPG Savings
01 2.1321: Replace fossil fuel equipment with electrical equipment $73,104 $121,444 $(-1,371.4)
(-37,066)
kWh
$(-1,832.2)
-
kW-mo/yr
- $76,307
-
MMBtu
02 2.4221: Install compressor air intakes in coolest locations $9,526 $9,755 $1,902
51,394
kWh
$7,624
-
kW-mo/yr
- -
03 2.4156: Establish a preventative maintenance program $829 $473 $71
1,915
kWh
$270
-
kW-mo/yr
$488
-
MMBtu
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $972 $26 $202
5,466
kWh
$770
-
kW-mo/yr
- -
05 2.4322: Use or replace with energy efficient substitutes $585 $3,626 $267
7,206
kWh
$318
-
kW-mo/yr
- -
06 2.6211: Conserve energy by efficient use of vending machines $529 - $241
6,526
kWh
$287
-
kW-mo/yr
- -
07 2.6212: Turn off equipment during breaks, reduce operating time $1,415 - $105
2,841
kWh
$1,310
-
kW-mo/yr
- -
08 2.7135: Install occupancy sensors $1,137 $2,018 $228
6,153
kWh
$910
-
kW-mo/yr
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $393 - $116
3,145
kWh
$276
-
kW-mo/yr
- -
10 2.7232: Replace existing hvac unit with high efficiency model $6,486 $80,718 $495
13,362
kWh
$4,680
-
kW-mo/yr
$1,311
-
MMBtu
-
11 2.7444: Close holes and openings in building such as broken windows $31 $57 $3
85
kWh
$3
-
kW-mo/yr
$24
-
MMBtu
-
12 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses $728 $22,678 - - $728
-
MMBtu
-
13 2.9114: Use solar heat to make electricty $6,362 $24,413 $1,320
35,682
kWh
$5,041
-
kW-mo/yr
- -
TOTAL RECOMMENDED $102,096 $265,208 $3,579
96,710
kWh
$19,658
-
kW-mo/yr
$2,552
-
MMBtu
$76,307
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs