Assessment Year | 1988 |
---|---|
Principal Product | AGITATION EQUIPMENT |
NAICS |
n/a
|
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 4,500,000
lb
|
Production Hrs. Annual | 0
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $302,720 | 4,846,424 |
kWh
|
$0.062 |
Natural Gas | $125,088 | 30,851 |
MMBtu
|
$4.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,882 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,456 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $3,170 | $9,000 |
$(-106.0)
(-1,758)
kWh
|
$3,276
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $3,210 | $3,000 | - |
$3,210
-
MMBtu
|
|
03 | 2.7446: Utilize sensors controlling roof and wall openings | $4,225 | $4,500 | - |
$4,225
-
MMBtu
|
|
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $311 | $600 | - |
$311
-
MMBtu
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $302 | - |
$302
4,982
kWh
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,920 | $1,000 |
$1,920
30,774
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,744 | $2,478 |
$1,744
27,843
kWh
|
- | |
TOTAL RECOMMENDED | $14,882 | $20,578 |
$3,860
61,841
kWh
|
$11,022
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,456 | $6,100 |
$1,920
30,774
kWh
|
$4,536
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs