Assessment Year 1991
Principal Product BLANKETS, BEDSPREADS
NAICS
n/a
SIC 2392: House furnishing, Except Curtains and Draperies
Sales Range $50
M
to 100
M
# of Employees 650
Plant Area
n/a
Annual Production 12,120,000
pieces
Production Hrs. Annual 8,232
hrs
Location (State) South Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,029,949 22,050,118
kWh
Natural Gas $225,315 49,675
MMBtu
Coal $200,751 143,220
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $56,284 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Coal Savings Administrative Changes Savings
01 2.2136: Install / repair insulation on steam lines $5,308 $2,090 - $5,308
-
MMBtu
-
02 2.2135: Repair and eliminate steam leaks $1,631 $770 - $1,631
-
MMBtu
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $13,017 - $13,017
276,964
kWh
- -
04 2.2511: Insulate bare equipment $1,295 $2,396 - $1,295
-
MMBtu
-
05 2.2135: Repair and eliminate steam leaks $1,013 $100 - $1,013
-
MMBtu
-
06 2.4221: Install compressor air intakes in coolest locations $5,813 $1,440 $5,813
123,681
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $6,746 - $8,430
179,367
kWh
- $(-1,684.0)
08 2.6232: Install set-back timers $1,708 - $1,708
36,342
kWh
- -
09 2.3191: Use demand controller or load shedder $19,753 $20,800 $19,753
-
kWh
- -
TOTAL RECOMMENDED $56,284 $27,596 $48,721
616,354
kWh
$9,247
-
MMBtu
$(-1,684.0)
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Coal Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs