Assessment Year | 1989 |
---|---|
Principal Product | RECORDING PAPER, TAPE |
NAICS |
n/a
|
SIC | 2672: Coated and Laminated Paper, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 240 |
Plant Area |
n/a
|
Annual Production | 2,500
ton
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $175,365 | 2,665,885 |
kWh
|
$0.066 |
Natural Gas | $275,607 | 58,901 |
MMBtu
|
$4.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,379 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,015 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $502 | $157 |
$502
7,620
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $1,015 | $840 |
$444
6,741
kWh
|
$571
-
MMBtu
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $1,081 | $500 |
$1,081
16,413
kWh
|
- | |
04 | 2.2443: Re-use or recycle hot or cold process exhaust air | $24,781 | $22,722 | - |
$24,781
-
MMBtu
|
|
TOTAL RECOMMENDED | $27,379 | $24,219 |
$2,027
30,774
kWh
|
$25,352
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,015 | $840 |
$444
6,741
kWh
|
$571
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs