Assessment Year | 2003 |
---|---|
Principal Product | Interior Molding |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 15 |
Plant Area |
57,000
ft2
|
Annual Production | 5,000,000
lb
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $199,531 | 2,202,000 |
kWh
|
$0.091 |
Electricity Demand | $104,337 | 9,528 |
kW-mo/yr
|
$10.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,789 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $1,176 | $134 |
$1,176
12,980
kWh
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,744 | $1,542 |
$1,362
15,033
kWh
|
$382
-
kW-mo/yr
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $924 | $587 |
$765
5,792
kWh
|
$159
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $678 | $1,749 |
$463
5,110
kWh
|
$215
-
kW-mo/yr
|
- | |
05 | 2.7145: Install skylights | $1,924 | $12,971 |
$1,322
14,592
kWh
|
$602
-
kW-mo/yr
|
- | |
06 | 2.3212: Optimize plant power factor | $7,343 | $11,038 | - | - | $7,343 | |
TOTAL RECOMMENDED | $13,789 | $28,021 |
$5,088
53,507
kWh
|
$1,358
-
kW-mo/yr
|
$7,343 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs