Assessment Year | 1988 |
---|---|
Principal Product | HAND OPER. CUTTING IMPL. |
NAICS |
n/a
|
SIC | 3421: Cutlery |
Sales Range | $10 M to 50M |
# of Employees | 113 |
Plant Area |
n/a
|
Annual Production | 1,600,000
pieces
|
Production Hrs. Annual | 2,375
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $64,890 | 830,891 |
kWh
|
$0.078 |
Fuel Oil #2 | $15,868 | 3,640 |
MMBtu
|
$4.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,216 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,022 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $556 | $1,340 |
$556
7,034
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $3,972 | $918 | - |
$3,972
-
MMBtu
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $586 | - |
$586
7,620
kWh
|
- | |
04 | 2.7442: Keep doors and windows shut when not on use | $1,494 | $1,085 | - |
$1,494
-
MMBtu
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $274 | $150 |
$274
3,517
kWh
|
- | |
06 | 2.4322: Use or replace with energy efficient substitutes | $2,334 | $1,880 | - |
$2,334
-
MMBtu
|
|
TOTAL RECOMMENDED | $9,216 | $5,373 |
$1,416
18,171
kWh
|
$7,800
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,022 | $3,343 |
$556
7,034
kWh
|
$5,466
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs