Assessment Year 1987
Principal Product FIBERGLASS BOATS & TRAIL
NAICS
n/a
SIC 3732: Boat Building and Repairing
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area
n/a
Annual Production 2,000
pieces
Production Hrs. Annual 2,500
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $42,833 647,421
kWh
Natural Gas $43,807 9,402
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,732 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,710

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,520 $563 $1,520
21,688
kWh
- -
02 2.7261: Install timers and/or thermostats $1,022 $388 $710
15,533
kWh
$312
-
MMBtu
-
03 2.4133: Use most efficient type of electric motors $473 $612 $473
6,741
kWh
- -
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $447 - $447
6,741
kWh
- -
05 2.6232: Install set-back timers $626 - $626
13,775
kWh
- -
06 2.7121: Utilize daylight whenever possible in lieu of artificial light $2,040 $3,860 $1,770
46,893
kWh
- $270
07 2.7442: Keep doors and windows shut when not on use $604 - $604
15,826
kWh
- -
TOTAL RECOMMENDED $6,732 $5,423 $6,150
127,197
kWh
$312
-
MMBtu
$270
TOTAL IMPLEMENTED $5,710 $5,035 $5,440
111,664
kWh
- $270
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs