| Assessment Year | 2019 |
|---|---|
| Principal Product | Fabricated Pipe |
| NAICS | 332996: Fabricated Pipe and Pipe Fitting Manufacturing |
| SIC | 3498: Fabricated Pipe and Pipe Fittings |
| Sales Range | $10 M to 50M |
| # of Employees | 43 |
| Plant Area |
50,000
ft2
|
| Annual Production | 20,000
pieces
|
| Production Hrs. Annual | 2,288
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $72,538 | 934,600 |
kWh
|
$0.078 |
| Electricity Demand | $10,696 | 2,596 |
kW-mo/yr
|
$4.12 |
| Other Gas | $85,820 | 17,164 |
MMBtu
|
$5.00 |
| TOTAL YEARLY COSTS | $169,054 | |||
| RECOMMENDED SAVINGS* | $17,547 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6231: Utilize controls to operate equipment only when needed | $5,663 | $250 |
$5,663
72,960
kWh
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $569 | $50 |
$569
7,329
kWh
|
- | |
| 03 | 2.6211: Conserve energy by efficient use of vending machines | $394 | $38 |
$367
4,730
kWh
|
$27
-
kW-mo/yr
|
|
| 04 | 2.7135: Install occupancy sensors | $105 | $50 |
$105
1,348
kWh
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,588 | $810 |
$1,588
20,462
kWh
|
- | |
| 06 | 2.6218: Turn off equipment when not in use | $129 | $104 |
$129
1,656
kWh
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,620 | $7,104 |
$6,744
86,825
kWh
|
$1,876
-
kW-mo/yr
|
|
| 08 | 2.7442: Keep doors and windows shut when not on use | $110 | $125 |
$110
1,417
kWh
|
- | |
| 09 | 2.7124: Make a practice of turning off lights when not needed | $369 | $500 |
$369
4,759
kWh
|
- | |
| TOTAL RECOMMENDED | $17,547 | $9,031 |
$15,644
201,486
kWh
|
$1,903
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs