Assessment Year 2015
Principal Product Helicopters
NAICS 336411: Aircraft Manufacturing
SIC 3721: Aircraft
Sales Range greater than $500
M
# of Employees 250
Plant Area 310,000
ft2
Annual Production 50
pieces
Production Hrs. Annual 5,616
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $319,431 5,474,398
kWh
Electricity Demand $39,320 11,076
kW-mo/yr
Electricity Fees $220,257 -
Natural Gas $430,785 37,058
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $75,856 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.7124: Make a practice of turning off lights when not needed $3,054 - $3,054
52,661
kWh
- - -
02 2.7261: Install timers and/or thermostats $8,822 - $8,822
152,100
kWh
- - -
03 2.4231: Reduce the pressure of compressed air to the minimum required $3,519 $40 $3,121
53,813
kWh
$398
-
kW-mo/yr
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,637 $1,000 $2,332
40,207
kWh
$305
-
kW-mo/yr
- -
05 2.7135: Install occupancy sensors $566 $240 $566
7,548
kWh
- - -
06 2.4221: Install compressor air intakes in coolest locations $292 $183 $240
4,146
kWh
$52
-
kW-mo/yr
- -
07 2.4323: Use optimum size and capacity equipment $1,372 $1,200 $1,372
23,659
kWh
- - -
08 2.7447: Install vinyl strip / high speed / air curtain doors $19,541 $18,800 $(-204.0)
(-3,525)
kWh
$(-358.0)
-
kW-mo/yr
$20,103
-
MMBtu
-
09 2.3131: Reschedule plant operations or reduce load to avoid peaks $1,966 $3,000 - $1,966
-
kW-mo/yr
- -
10 2.7135: Install occupancy sensors $224 $450 $224
3,868
kWh
- - -
11 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,768 $8,250 $3,335
57,503
kWh
$433
-
kW-mo/yr
- -
12 2.7261: Install timers and/or thermostats $4,108 $9,000 $4,108
70,834
kWh
- - -
13 2.7447: Install vinyl strip / high speed / air curtain doors $4,525 $1,500 - - $4,525
-
MMBtu
-
14 2.7232: Replace existing hvac unit with high efficiency model $13,437 $64,250 $10,713
184,704
kWh
$2,724
-
kW-mo/yr
- -
15 2.7142: Utilize higher efficiency lamps and/or ballasts $8,025 $41,790 $5,990
103,278
kWh
$781
-
kW-mo/yr
- $1,254
TOTAL RECOMMENDED $75,856 $149,703 $43,673
750,796
kWh
$6,301
-
kW-mo/yr
$24,628
-
MMBtu
$1,254
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs