ITAC Assessment: LE0174
ITAC logo
ITAC Assessment: LE0174
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2003
Principal Product Spherical Bearings
NAICS 332991: Ball and Roller Bearing Manufacturing
SIC 3562: Ball and Roller Bearings
Sales Range n/a
# of Employees 184
Plant Area 268,000
ft2
Annual Production 352,000
pieces
Production Hrs. Annual 7,200
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,098,064 25,948,309
kWh
Electricity Demand $438,295 45,895
kW-mo/yr
Natural Gas $411,282 70,451
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $66,994 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $47,260

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.2511: Insulate bare equipment $16,235 $262 - - $16,235
-
MMBtu
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $11,375 $48,722 $4,321
90,014
kWh
$1,423
-
kW-mo/yr
- $5,631
03 2.4221: Install compressor air intakes in coolest locations $13,320 $2,000 $9,582
199,637
kWh
$3,738
-
kW-mo/yr
- -
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $6,414 - $4,888
101,838
kWh
$1,526
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,251 $200 $4,694
97,798
kWh
$1,557
-
kW-mo/yr
- -
06 2.1233: Analyze flue gas for proper air/fuel ratio $5,746 $750 - - $5,746
-
MMBtu
-
07 2.7261: Install timers and/or thermostats $3,959 $1,050 $3,959
82,480
kWh
- - -
08 2.7124: Make a practice of turning off lights when not needed $2,585 - $2,585
53,865
kWh
- - -
09 2.7492: Use proper thickness of insulation on building envelope $656 - $656
13,669
kWh
- - -
10 2.7447: Install vinyl strip / high speed / air curtain doors $229 $1,100 $229
5,322
kWh
- - -
11 2.2136: Install / repair insulation on steam lines $224 $80 - - $224
-
MMBtu
-
TOTAL RECOMMENDED $66,994 $54,164 $30,914
644,623
kWh
$8,244
-
kW-mo/yr
$22,205
-
MMBtu
$5,631
TOTAL IMPLEMENTED $47,260 $52,164 $16,444
343,148
kWh
$2,980
-
kW-mo/yr
$22,205
-
MMBtu
$5,631
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs