Assessment Year | 1992 |
---|---|
Principal Product | GIFTWRAP,KEEPSAKES,CANDY |
NAICS |
n/a
|
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 483 |
Plant Area |
n/a
|
Annual Production | 493,098
pieces
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $541,220 | 11,971,278 |
kWh
|
$0.045 |
Natural Gas | $34,524 | 17,705 |
MMBtu
|
$1.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $69,573 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,061 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $23,557 | $93,650 |
$17,570
388,628
kWh
|
$5,987
-
MMBtu
|
- | |
02 | 2.7226: Use computer programs to optimize hvac performance | $10,269 | $73,000 |
$10,269
227,140
kWh
|
- | - | |
03 | 3.4115: Recover and reuse cooling water | $19,128 | - | - | - | $19,128 | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,815 | $1,000 |
$1,815
40,152
kWh
|
- | - | |
05 | 2.2437: Recover waste heat from equipment | $715 | $500 |
$(-53.0)
(-1,172)
kWh
|
$768
-
MMBtu
|
- | |
06 | 2.2511: Insulate bare equipment | $3,220 | $4,298 |
$3,220
71,219
kWh
|
- | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,034 | $4,860 |
$3,034
67,116
kWh
|
- | - | |
08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,375 | $3,500 | - |
$2,375
-
MMBtu
|
- | |
09 | 2.1222: Install turbulators | $1,424 | $1,000 | - |
$1,424
-
MMBtu
|
- | |
10 | 2.7446: Utilize sensors controlling roof and wall openings | $2,875 | $2,500 |
$2,875
63,599
kWh
|
- | - | |
11 | 2.6232: Install set-back timers | $1,153 | $1,200 |
$1,153
25,498
kWh
|
- | - | |
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8 | - |
$35
879
kWh
|
- | $(-27.0) | |
TOTAL RECOMMENDED | $69,573 | $185,508 |
$39,918
883,059
kWh
|
$10,554
-
MMBtu
|
$19,101 | ||
TOTAL IMPLEMENTED | $10,061 | $13,658 |
$6,289
139,214
kWh
|
$3,799
-
MMBtu
|
$(-27.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs