| Assessment Year | 2024 |
|---|---|
| Principal Product | Custom injection molding for consumer, medical, communications and automotive apps. |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 40 |
| Plant Area |
170,205
ft2
|
| Annual Production | 3,100,000
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $74,071 | 1,501,200 |
kWh
|
$0.049 | |
| Electricity Demand | $55,571 | 4,964 |
kW-mo/yr
|
$11.19 | |
| Electricity Fees | $5,919 | - |
|
- | |
| Waste Disposal Costs | |||||
| Water Usage | $952 | 799 |
Tgal
|
$1.19 | |
| Water Disposal | $408 | 343 |
Tgal
|
$1.19 | |
| TOTAL YEARLY COSTS | $136,921 | ||||
| RECOMMENDED SAVINGS* | $35,672 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $31,832 | $216,216 |
$23,226
470,714
kWh
|
$8,606
-
kW-mo/yr
|
- | |
| 02 | 2.7232: Replace existing hvac unit with high efficiency model | $2,706 | $7,350 |
$2,064
41,839
kWh
|
$641
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $727 | $2,781 |
$439
8,902
kWh
|
$287
-
kW-mo/yr
|
- | |
| 04 | 3.4155: Meter waste water | $408 | $1,511 | - | - |
$408
-
Tgal
|
|
| TOTAL RECOMMENDED | $35,672 | $227,858 |
$25,729
521,455
kWh
|
$9,535
-
kW-mo/yr
|
$408
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs