Assessment Year | 1991 |
---|---|
Principal Product | ALUMINUM FLASHLIGHTS |
NAICS |
n/a
|
SIC | 3648: Lighting Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 185 |
Plant Area |
n/a
|
Annual Production | 2,500,000
pieces
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $63,026 | 939,918 |
kWh
|
$0.067 |
Natural Gas | $7,334 | 1,672 |
MMBtu
|
$4.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,006 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,006 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $7,348 | $1,000 |
$6,092
90,856
kWh
|
$1,256
-
MMBtu
|
|
02 | 2.2437: Recover waste heat from equipment | $988 | $705 | - |
$988
-
MMBtu
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $275 | $100 |
$275
4,103
kWh
|
- | |
04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $825 | $200 |
$825
12,309
kWh
|
- | |
05 | 2.6232: Install set-back timers | $570 | $330 |
$570
8,499
kWh
|
- | |
TOTAL RECOMMENDED | $10,006 | $2,335 |
$7,762
115,767
kWh
|
$2,244
-
MMBtu
|
||
TOTAL IMPLEMENTED | $10,006 | $2,335 |
$7,762
115,767
kWh
|
$2,244
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs