Assessment Year | 1987 |
---|---|
Principal Product | MACHINED PARTS |
NAICS |
n/a
|
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 35 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,288
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $34,434 | 560,668 |
kWh
|
$0.061 |
Natural Gas | $14,942 | 3,406 |
MMBtu
|
$4.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,024 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $584 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $2,300 | $573 | - |
$2,300
-
MMBtu
|
- | |
02 | 2.2511: Insulate bare equipment | $140 | $360 | - |
$140
-
MMBtu
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $584 | - |
$684
11,723
kWh
|
- | $(-100.0) | |
TOTAL RECOMMENDED | $3,024 | $933 |
$684
11,723
kWh
|
$2,440
-
MMBtu
|
$(-100.0) | ||
TOTAL IMPLEMENTED | $584 | - |
$684
11,723
kWh
|
- | $(-100.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs