Assessment Year | 1991 |
---|---|
Principal Product | METALS |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 64 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $136,804 | 1,838,511 |
kWh
|
$0.074 |
Natural Gas | $39,181 | 9,551 |
MMBtu
|
$4.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,799 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,799 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.5194: Redesign process | $1,119 | - | - |
$1,119
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $3,551 | $3,600 | - |
$3,551
-
MMBtu
|
|
03 | 2.7243: Improve air circulation with destratification fans / other methods | $6,970 | $20,000 | - |
$6,970
-
MMBtu
|
|
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,825 | $4,000 | - |
$3,825
-
MMBtu
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $153 | - |
$153
2,052
kWh
|
- | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $2,398 | $200 |
$2,398
32,239
kWh
|
- | |
07 | 2.6232: Install set-back timers | $698 | $1,000 |
$698
9,379
kWh
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $85 | $84 |
$85
1,172
kWh
|
- | |
TOTAL RECOMMENDED | $18,799 | $28,884 |
$3,334
44,842
kWh
|
$15,465
-
MMBtu
|
||
TOTAL IMPLEMENTED | $18,799 | $28,884 |
$3,334
44,842
kWh
|
$15,465
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs