Assessment Year 1998
Principal Product Beverages & Tomato Products
NAICS
n/a
SIC 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 160,000
ft2
Annual Production 5,000,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $139,289 2,393,318
kWh
Electricity Demand $66,996 5,089
kW-mo/yr
Natural Gas $95,346 33,789
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $362,121 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,970

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $4,233 $10,320 $2,752
47,186
kWh
$1,481
-
kW-mo/yr
- - - -
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $458 $438 $315
5,275
kWh
$143
-
kW-mo/yr
- - - -
03 2.4133: Use most efficient type of electric motors $1,425 $2,899 $981
16,999
kWh
$444
-
kW-mo/yr
- - - -
04 2.2136: Install / repair insulation on steam lines $514 $831 - - $514
-
MMBtu
- - -
05 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $3,954 $4,750 $3,333
57,151
kWh
$621
-
kW-mo/yr
- - - -
06 2.7134: Use photocell controls $3,187 $2,250 $1,559
26,671
kWh
$1,628
-
kW-mo/yr
- - - -
07 2.6231: Utilize controls to operate equipment only when needed $1,535 $370 $1,179
20,223
kWh
$356
-
kW-mo/yr
- - - -
08 2.2135: Repair and eliminate steam leaks $1,580 $625 - - $1,580
-
MMBtu
- - -
09 2.4239: Eliminate or reduce compressed air usage $651 $175 $388
6,741
kWh
$263
-
kW-mo/yr
- - - -
10 2.4239: Eliminate or reduce compressed air usage $734 $3,180 $690
11,723
kWh
$44
-
kW-mo/yr
- - - -
11 3.4154: Eliminate leaks in water lines and valves $8,688 $6,000 $5,283
206,624
kWh
- - $3,405
-
Tgal
- -
12 3.5315: Lease / purchase baler; sell cardboard to recycler $16,282 $250 - - - - $16,282
-
lb
-
13 4.113: Install refrigeration system to cool product $318,880 $146,050 - - - - - $318,880
TOTAL RECOMMENDED $362,121 $178,138 $16,480
398,593
kWh
$4,980
-
kW-mo/yr
$2,094
-
MMBtu
$3,405
-
Tgal
$16,282
-
lb
$318,880
TOTAL IMPLEMENTED $24,970 $6,250 $5,283
206,624
kWh
- - $3,405
-
Tgal
$16,282
-
lb
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Solid Waste (non-haz) Savings Personnel Changes Savings