Assessment Year | 1998 |
---|---|
Principal Product | Beverages & Tomato Products |
NAICS |
n/a
|
SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
160,000
ft2
|
Annual Production | 5,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $139,289 | 2,393,318 |
kWh
|
$0.058 |
Electricity Demand | $66,996 | 5,089 |
kW-mo/yr
|
$13.16 |
Natural Gas | $95,346 | 33,789 |
MMBtu
|
$2.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $362,121 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,970 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,233 | $10,320 |
$2,752
47,186
kWh
|
$1,481
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $458 | $438 |
$315
5,275
kWh
|
$143
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $1,425 | $2,899 |
$981
16,999
kWh
|
$444
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.2136: Install / repair insulation on steam lines | $514 | $831 | - | - |
$514
-
MMBtu
|
- | - | - | |
05 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $3,954 | $4,750 |
$3,333
57,151
kWh
|
$621
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.7134: Use photocell controls | $3,187 | $2,250 |
$1,559
26,671
kWh
|
$1,628
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.6231: Utilize controls to operate equipment only when needed | $1,535 | $370 |
$1,179
20,223
kWh
|
$356
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.2135: Repair and eliminate steam leaks | $1,580 | $625 | - | - |
$1,580
-
MMBtu
|
- | - | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $651 | $175 |
$388
6,741
kWh
|
$263
-
kW-mo/yr
|
- | - | - | - | |
10 | 2.4239: Eliminate or reduce compressed air usage | $734 | $3,180 |
$690
11,723
kWh
|
$44
-
kW-mo/yr
|
- | - | - | - | |
11 | 3.4154: Eliminate leaks in water lines and valves | $8,688 | $6,000 |
$5,283
206,624
kWh
|
- | - |
$3,405
-
Tgal
|
- | - | |
12 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $16,282 | $250 | - | - | - | - |
$16,282
-
lb
|
- | |
13 | 4.113: Install refrigeration system to cool product | $318,880 | $146,050 | - | - | - | - | - | $318,880 | |
TOTAL RECOMMENDED | $362,121 | $178,138 |
$16,480
398,593
kWh
|
$4,980
-
kW-mo/yr
|
$2,094
-
MMBtu
|
$3,405
-
Tgal
|
$16,282
-
lb
|
$318,880 | ||
TOTAL IMPLEMENTED | $24,970 | $6,250 |
$5,283
206,624
kWh
|
- | - |
$3,405
-
Tgal
|
$16,282
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs