| Assessment Year | 1985 |
|---|---|
| Principal Product | PRINTED MAGAZINES |
| NAICS |
n/a
|
| SIC | 2752: Commercial Printing, Lithographic |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
n/a
|
| Annual Production | 20,000,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $151,392 | 2,380,422 |
kWh
|
$0.064 |
| Natural Gas | $25,689 | 5,715 |
MMBtu
|
$4.50 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,690 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,801 | $4,838 |
$3,801
59,789
kWh
|
- | - | |
| 02 | 2.2511: Insulate bare equipment | $3,684 | $782 |
$1,746
113,716
kWh
|
$1,938
-
MMBtu
|
- | |
| 03 | 2.4312: Improve lubrication practices | $5,315 | $2,000 |
$5,315
83,529
kWh
|
- | - | |
| 04 | 2.3191: Use demand controller or load shedder | $2,058 | $3,000 |
$2,058
-
kWh
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,210 | $4,973 |
$4,210
66,237
kWh
|
- | - | |
| 06 | 2.7261: Install timers and/or thermostats | $2,763 | $47 |
$261
4,103
kWh
|
$2,502
-
MMBtu
|
- | |
| 07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,074 | $7 |
$75
1,172
kWh
|
$999
-
MMBtu
|
- | |
| 08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $395 | - | - |
$495
-
MMBtu
|
$(-100.0) | |
| 09 | 2.1123: Install automatic stack damper | $405 | $700 | - |
$405
-
MMBtu
|
- | |
| 10 | 2.2437: Recover waste heat from equipment | $594 | $500 | - |
$594
-
MMBtu
|
- | |
| 11 | 2.4221: Install compressor air intakes in coolest locations | $391 | $150 |
$391
6,155
kWh
|
- | - | |
| TOTAL RECOMMENDED | $24,690 | $16,997 |
$17,857
334,701
kWh
|
$6,933
-
MMBtu
|
$(-100.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs