Assessment Year | 1984 |
---|---|
Principal Product | BOOKS |
NAICS |
n/a
|
SIC | 2732: Book Printing |
Sales Range | $5 M to 10M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 100,000,000
pieces
|
Production Hrs. Annual | 3,328
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,213 | 725,088 |
kWh
|
$0.080 |
Natural Gas | $12,551 | 2,940 |
MMBtu
|
$4.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,833 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,122 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 3.4157: Replace water cooling on processes with air cooling | $4,772 | $4,500 |
$424
5,275
kWh
|
$68
-
MMBtu
|
$4,280 | |
02 | 2.7261: Install timers and/or thermostats | $3,839 | - |
$2,588
32,239
kWh
|
$1,251
-
MMBtu
|
- | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $2,293 | - | - |
$2,293
-
MMBtu
|
- | |
04 | 2.7441: Replace broken windows and/or window sash | $250 | $90 |
$24
293
kWh
|
$226
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,930 | - |
$1,930
24,033
kWh
|
- | - | |
06 | 2.3191: Use demand controller or load shedder | $1,472 | $2,000 |
$1,472
-
kWh
|
- | - | |
07 | 2.7444: Close holes and openings in building such as broken windows | $1,169 | $400 |
$682
8,499
kWh
|
$487
-
MMBtu
|
- | |
08 | 2.5196: Use small number of high output units instead of many small inefficient units | $1,200 | $1,670 |
$1,200
14,947
kWh
|
- | - | |
09 | 2.2511: Insulate bare equipment | $754 | $750 |
$447
5,569
kWh
|
$307
-
MMBtu
|
- | |
10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $471 | $20 |
$471
5,862
kWh
|
- | - | |
12 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $235 | $50 |
$235
2,931
kWh
|
- | - | |
13 | 2.6121: Reduce hot water temperature to the minimum required | $212 | - |
$212
2,638
kWh
|
- | - | |
14 | 2.6121: Reduce hot water temperature to the minimum required | $118 | - |
$118
1,465
kWh
|
- | - | |
15 | 2.4221: Install compressor air intakes in coolest locations | $118 | $40 |
$118
1,465
kWh
|
- | - | |
TOTAL RECOMMENDED | $18,833 | $9,520 |
$9,921
105,216
kWh
|
$4,632
-
MMBtu
|
$4,280 | ||
TOTAL IMPLEMENTED | $6,122 | $50 |
$4,871
60,668
kWh
|
$1,251
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs