| Assessment Year | 1983 |
|---|---|
| Principal Product | CORRUGATED CONTAINERS |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
n/a
|
| Annual Production | 514,000
thousand feet
|
| Production Hrs. Annual | 6,048
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $243,230 | 4,216,882 |
kWh
|
$0.058 |
| Natural Gas | $163,049 | 54,158 |
MMBtu
|
$3.01 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $51,437 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $45,568 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,263 | $6,058 |
$20,263
351,407
kWh
|
- | |
| 02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $12,920 | $6,931 | - |
$12,920
-
MMBtu
|
|
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $4,647 | $20,000 | - |
$4,647
-
MMBtu
|
|
| 04 | 2.7261: Install timers and/or thermostats | $3,656 | $149 |
$678
11,723
kWh
|
$2,978
-
MMBtu
|
|
| 05 | 2.3212: Optimize plant power factor | $3,507 | $1,685 |
$3,507
-
kWh
|
- | |
| 06 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $1,291 | - |
$1,291
22,274
kWh
|
- | |
| 07 | 2.7314: Reduce ventilation air | $3,114 | - |
$2,222
38,687
kWh
|
$892
-
MMBtu
|
|
| 08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,464 | - |
$1,464
25,498
kWh
|
- | |
| 09 | 2.4221: Install compressor air intakes in coolest locations | $575 | $358 |
$575
9,965
kWh
|
- | |
| TOTAL RECOMMENDED | $51,437 | $35,181 |
$30,000
459,554
kWh
|
$21,437
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $45,568 | $35,181 |
$25,023
373,095
kWh
|
$20,545
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs