Assessment Year | 1982 |
---|---|
Principal Product | PLASTIC BOTTLES |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 13,800,000
lb
|
Production Hrs. Annual | 6,077
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $753,766 | 15,089,684 |
kWh
|
$0.050 |
Natural Gas | $36,216 | 12,598 |
MMBtu
|
$2.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $210,078 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,438 | $2,000 |
$10,438
208,968
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $4,890 | $4,800 |
$2,804
56,272
kWh
|
$2,086
-
MMBtu
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $8,989 | $550 |
$8,989
179,953
kWh
|
- | |
04 | 2.2444: Use hot process fluids to preheat incoming process fluids | $162,065 | $20,000 |
$162,065
3,244,431
kWh
|
- | |
05 | 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads | $20,364 | $40,000 |
$20,364
407,679
kWh
|
- | |
06 | 2.7444: Close holes and openings in building such as broken windows | $3,332 | $818 | - |
$3,332
-
MMBtu
|
|
TOTAL RECOMMENDED | $210,078 | $68,168 |
$204,660
4,097,303
kWh
|
$5,418
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs