Assessment Year | 1982 |
---|---|
Principal Product | PRINTING AND PLASTICS |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $1 M to 5M |
# of Employees | 90 |
Plant Area |
n/a
|
Annual Production | 200,000
pieces
|
Production Hrs. Annual | 5,313
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $57,128 | 898,007 |
kWh
|
$0.064 |
Natural Gas | $12,710 | 4,600 |
MMBtu
|
$2.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,930 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $740 | $100 |
$740
11,723
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,997 | $3,000 |
$2,997
47,186
kWh
|
- | |
03 | 2.6121: Reduce hot water temperature to the minimum required | $439 | - |
$369
5,862
kWh
|
$70
-
MMBtu
|
|
04 | 2.7261: Install timers and/or thermostats | $1,297 | $500 | - |
$1,297
-
MMBtu
|
|
05 | 2.7444: Close holes and openings in building such as broken windows | $3,146 | $3,500 | - |
$3,146
-
MMBtu
|
|
06 | 2.5194: Redesign process | $11,311 | $80,000 |
$11,311
177,902
kWh
|
- | |
TOTAL RECOMMENDED | $19,930 | $87,100 |
$15,417
242,673
kWh
|
$4,513
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs