ITAC Assessment: IC0156
ITAC logo
ITAC Assessment: IC0156
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2009
Principal Product Toaster Pastries and Baked Goods
NAICS 311821: Cookie and Cracker Manufacturing
SIC 2052: Cookies and Crackers
Sales Range $5
M
to 10
M
# of Employees 300
Plant Area 311,300
ft2
Annual Production 86,950,000
lb
Production Hrs. Annual 6,808
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $829,890 10,920,301
kWh
Electricity Demand $118,152 21,993
kW-mo/yr
Natural Gas $912,152 193,754
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $54,484 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $42,693

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7131: Add area lighting switches $10,860 $8,096 $9,898
130,237
kWh
$962
-
kW-mo/yr
-
02 2.7135: Install occupancy sensors $4,252 $4,247 $3,786
49,820
kWh
$466
-
kW-mo/yr
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,116 $1,649 $906
11,908
kWh
$210
-
kW-mo/yr
-
04 2.7122: Disconnect ballasts $2,089 $2,200 $1,858
24,444
kWh
$231
-
kW-mo/yr
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $14,483 $29,250 $12,808
168,519
kWh
$1,675
-
kW-mo/yr
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $1,309 $5,917 $1,191
16,320
kWh
$118
-
kW-mo/yr
-
07 2.4151: Develop a repair/replace policy $4,792 $15,044 $4,261
56,054
kWh
$531
-
kW-mo/yr
-
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,513 $1,610 $3,513
44,694
kWh
- -
09 2.4226: Use / purchase optimum sized compressor $8,278 $7,995 $8,278
108,928
kWh
- -
10 2.6211: Conserve energy by efficient use of vending machines $934 - $547
7,200
kWh
$387
-
kW-mo/yr
-
11 2.2136: Install / repair insulation on steam lines $1,559 $2,887 - - $1,559
-
MMBtu
12 2.7261: Install timers and/or thermostats $1,299 - - - $1,299
-
MMBtu
TOTAL RECOMMENDED $54,484 $78,895 $47,046
618,124
kWh
$4,580
-
kW-mo/yr
$2,858
-
MMBtu
TOTAL IMPLEMENTED $42,693 $69,290 $35,255
464,502
kWh
$4,580
-
kW-mo/yr
$2,858
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs