ITAC Assessment: IA0054
ITAC logo
ITAC Assessment: IA0054
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1993
Principal Product wood and gas fireplaces and wood sto
NAICS
n/a
SIC 3433: Heating Equipment, Except Electric and Warm Air Furnaces
Sales Range $10
M
to 50
M
# of Employees 400
Plant Area 297,000
ft2
Annual Production 120,000
pieces
Production Hrs. Annual 6,528
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $359,995 6,242,966
kWh
Natural Gas $112,989 26,360
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $80,378 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $17,555

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.8113: Purchase gas directly from a contract gas supplier $22,406 $6,700 - - $22,406
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $13,866 $1,000 $13,866
240,328
kWh
- -
03 2.2437: Recover waste heat from equipment $11,087 $150 - $11,087
-
MMBtu
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $9,407 $5,130 $9,407
163,247
kWh
- -
05 2.4221: Install compressor air intakes in coolest locations $544 $150 $544
9,379
kWh
- -
06 2.3131: Reschedule plant operations or reduce load to avoid peaks $8,923 $18,450 - $8,923
-
MMBtu
-
07 2.8121: Apply for tax-free status for energy purchases $3,116 $250 - - $3,116
08 2.2428: Use flue gases in radiant heater for space heating, ovens, etc $6,016 $5,860 - $6,016
-
MMBtu
-
09 2.4133: Use most efficient type of electric motors $1,157 $1,840 $1,157
20,223
kWh
- -
10 2.7261: Install timers and/or thermostats $1,107 - - $1,107
-
MMBtu
-
11 2.7447: Install vinyl strip / high speed / air curtain doors $761 $880 - $761
-
MMBtu
-
12 2.7142: Utilize higher efficiency lamps and/or ballasts $1,093 $72 $1,093
19,050
kWh
- -
13 2.7135: Install occupancy sensors $895 $1,359 $895
15,533
kWh
- -
TOTAL RECOMMENDED $80,378 $41,841 $26,962
467,760
kWh
$27,894
-
MMBtu
$25,522
TOTAL IMPLEMENTED $17,555 $4,421 $17,555
304,513
kWh
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs