Assessment Year 1992
Principal Product FARM IMPLEMENTS
NAICS
n/a
SIC 3523: Farm Machinery and Equipment
Sales Range $10
M
to 50
M
# of Employees 110
Plant Area
n/a
Annual Production 10,000,000
pieces
Production Hrs. Annual 6,656
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $161,779 3,395,956
kWh
Natural Gas $33,554 7,961
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $21,537 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $15,033

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $12,878 $17,000 $20,498
423,505
kWh
$(-7,620.0)
-
MMBtu
-
02 2.7261: Install timers and/or thermostats $2,727 $1,000 $1,178
24,326
kWh
$1,549
-
MMBtu
-
03 2.7447: Install vinyl strip / high speed / air curtain doors $286 $1,030 - $286
-
MMBtu
-
04 2.7447: Install vinyl strip / high speed / air curtain doors $346 $371 - $346
-
MMBtu
-
05 2.4133: Use most efficient type of electric motors $704 $6,500 $704
14,654
kWh
- -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,441 $100 $2,441
50,410
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $403 $811 $403
16,706
kWh
- -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $811 $126 $937
19,343
kWh
- $(-126.0)
09 2.6232: Install set-back timers $941 $400 $941
19,343
kWh
- -
TOTAL RECOMMENDED $21,537 $27,338 $27,102
568,287
kWh
$(-5,439.0)
-
MMBtu
$(-126.0)
TOTAL IMPLEMENTED $15,033 $18,337 $22,779
478,897
kWh
$(-7,620.0)
-
MMBtu
$(-126.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs