| Assessment Year | 1982 |
|---|---|
| Principal Product | MAGNET WIRE |
| NAICS |
n/a
|
| SIC | 3357: Drawing and Insulating of Nonferrous Wire |
| Sales Range | $10 M to 50M |
| # of Employees | 78 |
| Plant Area |
n/a
|
| Annual Production | 9,000,000
lb
|
| Production Hrs. Annual | 5,880
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $306,722 | 7,878,957 |
kWh
|
$0.039 |
| Natural Gas | $131,729 | 33,093 |
MMBtu
|
$3.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,641 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $8,459 | - |
$8,459
-
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,881 | $5,192 |
$3,881
99,648
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $3,301 | $3,296 |
$3,301
84,994
kWh
|
|
| TOTAL RECOMMENDED | $15,641 | $8,488 |
$15,641
184,642
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs