ITAC Assessment: DL0235
ITAC logo
ITAC Assessment: DL0235
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Precision custom metal parts
NAICS 332721: Precision Turned Product Manufacturing
SIC 3451: Screw Machine Products
Sales Range $50
M
to 100
M
# of Employees 120
Plant Area 44,000
ft2
Annual Production 100,000
units
Production Hrs. Annual 5,500
hrs
Location (State) Maryland

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $230,941 2,371,719
kWh
Electricity Demand $26,567 5,811
kW-mo/yr
Electricity Fees $1,164 -
TOTAL YEARLY COSTS $258,672
RECOMMENDED SAVINGS* $31,574 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.6231: Utilize controls to operate equipment only when needed $719 - $719
6,597
kWh
02 2.7261: Install timers and/or thermostats $751 $800 $751
6,887
kWh
03 2.6231: Utilize controls to operate equipment only when needed $2,885 $500 $2,885
26,471
kWh
04 2.6231: Utilize controls to operate equipment only when needed $24,674 $10,000 $24,674
223,369
kWh
05 2.7447: Install vinyl strip / high speed / air curtain doors $646 $3,000 $646
5,928
kWh
06 2.7314: Reduce ventilation air $1,085 - $1,085
9,951
kWh
07 2.6122: Adjust vents to minimize energy use $814 $1,500 $814
7,464
kWh
TOTAL RECOMMENDED $31,574 $15,800 $31,574
286,667
kWh
TOTAL IMPLEMENTED - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs