Assessment Year | 2023 |
---|---|
Principal Product | Plastic Sheets |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 45 |
Plant Area |
104,000
ft2
|
Annual Production | 100,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $204,439 | 2,348,707 |
kWh
|
$0.087 | |
Electricity Demand | $52,084 | 5,148 |
kW-mo/yr
|
$10.12 | |
Electricity Fees | $10,702 | - |
|
- | |
LPG | $29,570 | 1,777 |
MMBtu
|
$16.64 | |
Waste Disposal Costs | |||||
Water Usage | $949 | 64 |
Tgal
|
$14.83 | |
TOTAL YEARLY COSTS | $297,744 | ||||
RECOMMENDED SAVINGS* | $92,922 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $92,922 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.7311: Ventilation system to shut off when room is not in use | $1,952 | - |
$391
3,586
kWh
|
$1,561
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $4,060 | $166 | - |
$4,060
-
MMBtu
|
|
03 | 2.6231: Utilize controls to operate equipment only when needed | $848 | - |
$848
7,775
kWh
|
- | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $1,563 | - |
$1,563
14,342
kWh
|
- | |
05 | 2.7261: Install timers and/or thermostats | $10,552 | $112 |
$7,823
71,775
kWh
|
$2,729
-
MMBtu
|
|
06 | 2.7261: Install timers and/or thermostats | $7,288 | $84 |
$1,830
16,788
kWh
|
$5,458
-
MMBtu
|
|
07 | 2.6231: Utilize controls to operate equipment only when needed | $2,850 | $1,637 |
$2,850
26,147
kWh
|
- | |
08 | 2.2437: Recover waste heat from equipment | $2,946 | $10,000 |
$231
2,118
kWh
|
$2,715
-
MMBtu
|
|
09 | 2.2437: Recover waste heat from equipment | $9,568 | $10,000 | - |
$9,568
-
MMBtu
|
|
10 | 2.6212: Turn off equipment during breaks, reduce operating time | $546 | - |
$546
5,008
kWh
|
- | |
11 | 2.2511: Insulate bare equipment | $500 | $340 |
$500
4,590
kWh
|
- | |
12 | 2.6231: Utilize controls to operate equipment only when needed | $5,886 | $5,000 |
$5,886
54,000
kWh
|
- | |
13 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,930 | $7,995 |
$4,930
45,229
kWh
|
- | |
14 | 2.4131: Size electric motors for peak operating efficiency | $9,758 | $1,500 |
$9,758
89,520
kWh
|
- | |
15 | 2.4224: Upgrade controls on compressors | $6,886 | $20,000 |
$6,886
63,177
kWh
|
- | |
16 | 2.4224: Upgrade controls on compressors | $14,220 | $30,000 |
$14,220
130,455
kWh
|
- | |
17 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,477 | $2,488 |
$4,477
41,075
kWh
|
- | |
18 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,092 | $10,000 |
$4,092
37,538
kWh
|
- | |
TOTAL RECOMMENDED | $92,922 | $99,322 |
$66,831
613,123
kWh
|
$26,091
-
MMBtu
|
||
TOTAL IMPLEMENTED | $92,922 | $99,322 |
$66,831
613,123
kWh
|
$26,091
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs