Assessment Year | 2013 |
---|---|
Principal Product | appliques, molded and formed parts |
NAICS | 323113: Commercial Screen Printing |
SIC | 3841: Surgical and Medical Instruments and Apparatus |
Sales Range | $50 M to 100M |
# of Employees | 310 |
Plant Area |
168,000
ft2
|
Annual Production | 91,522,665
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $958,181 | 13,107,637 |
kWh
|
$0.073 |
Electricity Demand | $145,293 | 26,312 |
kW-mo/yr
|
$5.52 |
Natural Gas | $198,558 | 40,566 |
MMBtu
|
$4.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,803 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,523 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $12,280 | $30,697 | - |
$12,280
-
kW-mo/yr
|
- | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,779 | $6,480 |
$1,207
20,890
kWh
|
- |
$1,572
-
MMBtu
|
|
03 | 2.2511: Insulate bare equipment | $2,744 | $2,303 | - | - |
$2,744
-
MMBtu
|
|
TOTAL RECOMMENDED | $17,803 | $39,480 |
$1,207
20,890
kWh
|
$12,280
-
kW-mo/yr
|
$4,316
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,523 | $8,783 |
$1,207
20,890
kWh
|
- |
$4,316
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs