Assessment Year | 2014 |
---|---|
Principal Product | Composite Parts & Laminates |
NAICS | 326130: Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing |
SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
Sales Range | $5 M to 10M |
# of Employees | 44 |
Plant Area |
47,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,602
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $81,299 | 618,785 |
kWh
|
$0.13 |
Natural Gas | $73,756 | 7,282 |
MMBtu
|
$10.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $61,647 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $33,440 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,820 | $17,500 |
$10,820
82,600
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,480 | $1,375 |
$3,480
26,019
kWh
|
- | |
03 | 2.4226: Use / purchase optimum sized compressor | $2,657 | $2,600 |
$2,657
20,285
kWh
|
- | |
04 | 2.7261: Install timers and/or thermostats | $11,450 | $1,000 | - |
$11,450
-
MMBtu
|
|
05 | 2.2437: Recover waste heat from equipment | $5,000 | $3,000 | - |
$5,000
-
MMBtu
|
|
06 | 2.2437: Recover waste heat from equipment | $3,800 | $4,000 | - |
$3,800
-
MMBtu
|
|
07 | 2.4131: Size electric motors for peak operating efficiency | $2,920 | $1,000 |
$2,920
22,329
kWh
|
- | |
08 | 2.6231: Utilize controls to operate equipment only when needed | $1,350 | $1,600 |
$1,350
10,290
kWh
|
- | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,580 | $7,000 |
$4,580
34,990
kWh
|
- | |
10 | 2.6218: Turn off equipment when not in use | $860 | - | - |
$860
-
MMBtu
|
|
11 | 2.6218: Turn off equipment when not in use | $8,380 | - | - |
$8,380
-
MMBtu
|
|
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,320 | $13,455 |
$4,320
32,970
kWh
|
- | |
13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,030 | $14,000 |
$2,030
15,475
kWh
|
- | |
TOTAL RECOMMENDED | $61,647 | $66,530 |
$32,157
244,958
kWh
|
$29,490
-
MMBtu
|
||
TOTAL IMPLEMENTED | $33,440 | $30,830 |
$12,750
96,793
kWh
|
$20,690
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs