| Assessment Year | 1993 |
|---|---|
| Principal Product | Printed Products |
| NAICS |
n/a
|
| SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
| Sales Range | $10 M to 50M |
| # of Employees | 214 |
| Plant Area |
133,880
ft2
|
| Annual Production | 3,000,000
lb
|
| Production Hrs. Annual | 4,472
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $357,217 | 5,717,761 |
kWh
|
$0.062 |
| Natural Gas | $125,089 | 32,575 |
MMBtu
|
$3.84 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $51,630 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,980 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,380 | $650 |
$3,380
54,220
kWh
|
- | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $1,310 | $700 |
$1,310
21,102
kWh
|
- | |
| 03 | 2.2437: Recover waste heat from equipment | $1,250 | $1,300 | - |
$1,250
-
MMBtu
|
|
| 04 | 2.7261: Install timers and/or thermostats | $6,370 | $5,550 | - |
$6,370
-
MMBtu
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $6,350 | $11,330 |
$6,350
101,700
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,890 | $2,770 |
$6,890
110,199
kWh
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $250 | $370 |
$250
4,103
kWh
|
- | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,880 | $55,200 |
$13,880
222,157
kWh
|
- | |
| 09 | 2.2437: Recover waste heat from equipment | $5,030 | $6,000 | - |
$5,030
-
MMBtu
|
|
| 10 | 2.7447: Install vinyl strip / high speed / air curtain doors | $390 | $1,120 | - |
$390
-
MMBtu
|
|
| 11 | 2.7243: Improve air circulation with destratification fans / other methods | $6,530 | $18,000 |
$(-940.0)
(-16,120)
kWh
|
$7,470
-
MMBtu
|
|
| TOTAL RECOMMENDED | $51,630 | $102,990 |
$31,120
497,361
kWh
|
$20,510
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $10,980 | $13,280 |
$9,730
155,920
kWh
|
$1,250
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs