ITAC Assessment: OK0057
ITAC logo
ITAC Assessment: OK0057
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1982
Principal Product WOOD & METAL FENCE
NAICS
n/a
SIC 3496: Miscellaneous Fabricated Wire Products
Sales Range $10
M
to 50
M
# of Employees 125
Plant Area
n/a
Annual Production 12,000
thousand feet
Production Hrs. Annual 6,000
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $141,153 1,871,043
kWh
Natural Gas $70,645 25,838
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $45,147 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $37,936

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $761 $2,402 $761
10,551
kWh
-
02 2.1233: Analyze flue gas for proper air/fuel ratio $12,500 $500 - $12,500
-
MMBtu
03 2.3212: Optimize plant power factor $20,704 $36,360 $20,704
-
kWh
-
04 2.3511: Use plant owned transformers or lease transformers $6,450 $19,800 $6,450
-
kWh
-
05 2.2514: Cover open tanks $640 $655 - $640
-
MMBtu
06 2.7261: Install timers and/or thermostats $4,092 $1,100 $4,092
120,164
kWh
-
TOTAL RECOMMENDED $45,147 $60,817 $32,007
130,715
kWh
$13,140
-
MMBtu
TOTAL IMPLEMENTED $37,936 $38,615 $24,796
120,164
kWh
$13,140
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs