| Assessment Year | 1982 |
|---|---|
| Principal Product | WOOD & METAL FENCE |
| NAICS |
n/a
|
| SIC | 3496: Miscellaneous Fabricated Wire Products |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
n/a
|
| Annual Production | 12,000
thousand feet
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $141,153 | 1,871,043 |
kWh
|
$0.075 |
| Natural Gas | $70,645 | 25,838 |
MMBtu
|
$2.73 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $45,147 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $37,936 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $761 | $2,402 |
$761
10,551
kWh
|
- | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $12,500 | $500 | - |
$12,500
-
MMBtu
|
|
| 03 | 2.3212: Optimize plant power factor | $20,704 | $36,360 |
$20,704
-
kWh
|
- | |
| 04 | 2.3511: Use plant owned transformers or lease transformers | $6,450 | $19,800 |
$6,450
-
kWh
|
- | |
| 05 | 2.2514: Cover open tanks | $640 | $655 | - |
$640
-
MMBtu
|
|
| 06 | 2.7261: Install timers and/or thermostats | $4,092 | $1,100 |
$4,092
120,164
kWh
|
- | |
| TOTAL RECOMMENDED | $45,147 | $60,817 |
$32,007
130,715
kWh
|
$13,140
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $37,936 | $38,615 |
$24,796
120,164
kWh
|
$13,140
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs