| Assessment Year | 1990 |
|---|---|
| Principal Product | FILM FOR CIRCUIT BOARDS |
| NAICS |
n/a
|
| SIC | 3624: Carbon and Graphite Products |
| Sales Range | $10 M to 50M |
| # of Employees | 320 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $855,034 | 17,808,031 |
kWh
|
$0.048 |
| Natural Gas | $282,182 | 77,282 |
MMBtu
|
$3.65 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $55,038 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $52,338 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $13,200 | $6,600 |
$13,200
275,791
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $4,900 | $3,517 |
$4,900
102,286
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,407 | $6,362 |
$14,407
300,410
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $9,070 | $2,400 |
$8,720
163,540
kWh
|
$350
-
MMBtu
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,198 | $4,667 |
$1,198
24,912
kWh
|
- | |
| 06 | 2.6232: Install set-back timers | $3,236 | $5,000 |
$3,236
67,409
kWh
|
- | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $2,997 | $2,000 |
$2,997
62,427
kWh
|
- | |
| 08 | 2.7261: Install timers and/or thermostats | $3,330 | $3,000 |
$1,830
38,101
kWh
|
$1,500
-
MMBtu
|
|
| 09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,700 | $5,700 |
$2,700
55,979
kWh
|
- | |
| TOTAL RECOMMENDED | $55,038 | $39,246 |
$53,188
1,090,855
kWh
|
$1,850
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $52,338 | $33,546 |
$50,488
1,034,876
kWh
|
$1,850
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs