Assessment Year | 1988 |
---|---|
Principal Product | ALUMINUM WINDOWS & DOORS |
NAICS |
n/a
|
SIC | 3341: Secondary Smelting and Refining of Nonferrous Metals |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
n/a
|
Annual Production | 5,961
ton
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $257,715 | 3,409,144 |
kWh
|
$0.076 |
Natural Gas | $127,791 | 34,544 |
MMBtu
|
$3.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,739 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,400 | $500 |
$1,400
18,464
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $1,032 | $1,000 | - |
$1,032
-
MMBtu
|
|
03 | 2.8113: Purchase gas directly from a contract gas supplier | $12,780 | $2,000 | - |
$12,780
-
MMBtu
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $239 | - |
$239
3,224
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,277 | $3,000 |
$2,277
30,188
kWh
|
- | |
06 | 2.1123: Install automatic stack damper | $574 | $1,000 | - |
$574
-
MMBtu
|
|
07 | 2.7441: Replace broken windows and/or window sash | $1,800 | $3,200 | - |
$1,800
-
MMBtu
|
|
08 | 2.7261: Install timers and/or thermostats | $544 | $300 | - |
$544
-
MMBtu
|
|
09 | 2.6218: Turn off equipment when not in use | $1,323 | $200 |
$718
9,379
kWh
|
$605
-
MMBtu
|
|
10 | 2.2425: Use flue gases to heat process or service water | $5,235 | $20,000 | - |
$5,235
-
MMBtu
|
|
11 | 2.2511: Insulate bare equipment | $759 | $1,760 | - |
$759
-
MMBtu
|
|
12 | 2.2511: Insulate bare equipment | $653 | $420 | - |
$653
-
MMBtu
|
|
13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $123 | $206 |
$123
1,758
kWh
|
- | |
TOTAL RECOMMENDED | $28,739 | $33,586 |
$4,757
63,013
kWh
|
$23,982
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs