Assessment Year 1985
Principal Product FABRICATED VEHICLE EQUIP
NAICS
n/a
SIC 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 230
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 2,160
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $140,680 2,895,076
kWh
Natural Gas $90,399 19,967
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $31,736 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $26,815

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $2,161 $6,500 $4,716
132,181
kWh
$(-2,555.0)
-
MMBtu
02 2.7261: Install timers and/or thermostats $16,221 $2,791 $2,264
46,600
kWh
$13,957
-
MMBtu
03 2.6212: Turn off equipment during breaks, reduce operating time $888 $200 - $888
-
MMBtu
04 2.4221: Install compressor air intakes in coolest locations $159 $200 $159
3,224
kWh
-
05 2.7492: Use proper thickness of insulation on building envelope $1,313 $1,600 - $1,313
-
MMBtu
06 2.7441: Replace broken windows and/or window sash $6,022 $1,570 $28
586
kWh
$5,994
-
MMBtu
07 2.7494: Install storm windows and doors $985 $750 - $985
-
MMBtu
08 2.1233: Analyze flue gas for proper air/fuel ratio $2,212 $800 - $2,212
-
MMBtu
09 2.1222: Install turbulators $793 $1,000 - $793
-
MMBtu
10 2.4312: Improve lubrication practices $157 - $157
3,224
kWh
-
11 2.7142: Utilize higher efficiency lamps and/or ballasts $825 $3,564 $825
16,999
kWh
-
TOTAL RECOMMENDED $31,736 $18,975 $8,149
202,814
kWh
$23,587
-
MMBtu
TOTAL IMPLEMENTED $26,815 $7,161 $2,451
50,410
kWh
$24,364
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs