30

matching recommendations
$
$
ARC 2+ Digits Required
NAICS 3+ Digits Required
SIC Silverware, plated ware, and stainless steel ware
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
IA0551 #06 Y:2015 Install occupancy sensors $527 $2,380
IA0551 #05 Y:2015 Reduce the pressure of compressed air to the minimum required $854 $70
IA0551 #04 Y:2015 Eliminate or reduce compressed air usage $989 $330
IA0551 #03 Y:2015 Utilize higher efficiency lamps and/or ballasts $1,021 $2,627
IA0551 #02 Y:2015 Eliminate leaks in inert gas and compressed air lines/ valves $1,938 $578
IA0551 #01 Y:2015 Utilize higher efficiency lamps and/or ballasts $12,782 $23,025
SU0396 #12 Y:2015 Add area lighting switches $781 $3,851
SU0396 #11 Y:2015 Conserve energy by efficient use of vending machines $112 $462
SU0396 #10 Y:2015 Install compressor air intakes in coolest locations $419 -
SU0396 #09 Y:2015 Eliminate/reduce an operation $1,222 $2,440
SU0396 #08 Y:2015 Replace existing hvac unit with high efficiency model $18,009 $17,408
SU0396 #07 Y:2015 Eliminate leaks in inert gas and compressed air lines/ valves $1,544 $1,250
SU0396 #06 Y:2015 Replace electrically-operated equipment with fossil fuel equipment $17,027 $20,360
SU0396 #05 Y:2015 Utilize higher efficiency lamps and/or ballasts $1,889 $930
SU0396 #04 Y:2015 Check for accuracy of utility / power meters $243 -
SU0396 #03 Y:2015 Reduce the pressure of compressed air to the minimum required $486 -
SU0396 #02 Y:2015 Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads $738 -
SU0396 #01 Y:2015 Pay bills on time to avoid late fees $813 -
UD0471 #06 Y:1995 Utilize a central coolant system for cleaning and reuse of metal working fluid $54,000 $7,500
UD0471 #05 Y:1995 Meter recycled water (to reduce sewer charges) $1,313 $200