Assessment Year 2016
Principal Product Cutlery
NAICS 332215: Metal Kitchen Cookware, Utensil, Cutlery, and Flatware (except Precious) Manufacturing
SIC 3914: Silverware, Plated Ware, and Stainless Steel Ware
Sales Range $10
M
to 50
M
# of Employees 107
Plant Area 48,000
ft2
Annual Production 4,000,000
pieces
Production Hrs. Annual 4,335
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $61,218 963,072
kWh
Electricity Demand $40,410 3,936
kW-mo/yr
Natural Gas $33,323 6,080
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $18,111 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $17,584

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $12,782 $23,025 $8,394
131,544
kWh
$4,388
-
kW-mo/yr
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,938 $578 $1,305
20,358
kWh
$633
-
kW-mo/yr
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,021 $2,627 $1,021
16,004
kWh
-
04 2.4239: Eliminate or reduce compressed air usage $989 $330 $663
10,387
kWh
$326
-
kW-mo/yr
05 2.4231: Reduce the pressure of compressed air to the minimum required $854 $70 $572
8,970
kWh
$282
-
kW-mo/yr
06 2.7135: Install occupancy sensors $527 $2,380 $527
8,271
kWh
-
TOTAL RECOMMENDED $18,111 $29,010 $12,482
195,534
kWh
$5,629
-
kW-mo/yr
TOTAL IMPLEMENTED $17,584 $26,630 $11,955
187,263
kWh
$5,629
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs